EPI XST SERIES

XSM/XST
10-60kVA
MULTI PHASE INPUT/OUTPUT (CONFIGURABLE)
ON-LINE DOUBLE CONVERSION

COMPLETE COST-EFFECTIVE SOLUTION

  • Online double conversion mode with an output power factor of 0.9 providing 12% more active power compares to UPS with a power factor of 0.8.
  • Dual input mains allow you to manage independent power sources
  • Increased system availability placing UPS in parallel for N+X redundancy .
  • Internal manual bypass for easy maintenance without power interruption .
  • Up to 12pcs parallelable
  • Multilanguage big LCD display

HIGH PERFORMANCE PFC RECTIFIER Thanks  to the  technology  used,  XSM / XST  solves  installation  problems  in  systems  where  the  power supply  has  limited  installed  power,  where  the  UPS  is  also  powered  by  a  generator  or  where there  are  compatibility  problems  with  loads  that  generate  harmonic  currents;  XSM / XST  has  zero impact on its power source, being either the mains power supply or a generator:

  • Input current distortion of less than 3%
  • Input power factor 0.99
  • Power walk-in function that ensures a progressive start-up of the rectifier
  • Start-up delay function, to restart the rectifiers when mains power is restored if there are several XSM / XST in the system.
  • In addition, XSM / XST plays a filter and power factor correction role in the power network upstream of the UPS, as it  eliminates  harmonic  components  and the reactive power, generated by the powered utilities.

Built-in  automatic  bypass  —  Transfers  the  load  to bypass in the unlikely event that a fault occurs in the UPS.

Optional  maintenance  bypass  distribution  cabinet  —  Provides  complete  wrap-around maintenance  bypass  allowing  XSM / XST  to  be  powered  down  or  taken  out  of  service  without disconnecting power to the load.

Optional  internal  batteries  —  Batteries  can  be  housed  within  the  XSM / XST  itself.  Easy  change of batteries with internal drawer type shelves.  Optional  XSM / XST  looking  external  battery  cabinets  —  Provide  added  back-up  capacity  for extended runtimes.

  • Monitoring of the switches and external bypass — Switches can be monitored through LCD and Modbus.

Advanced communications

XSM / XST is equipped with a back-lit graphic display providing UPS information, measurements, operating states and alarms in different languages. It can also display wave forms and voltage/ current forms

Maximum reliability and availability

Distributed parallel configuration of up to 6 units per redundant (N+1) or power parallel system. The UPS continue to operate in parallel even if the connection cable is interrupted

TAILORED TO YOUR ENVIRONMENT

  • Saves space with a reduced footprint and optimized cabinet size.
  • Low noise level with intelligent fan speed control.
  • Flexible battery solutions • Compact, lightweight and easy to install
  • Extended battery life with exclusive battery charging management for increased battery life.
  • Easy service by the help of modular power board concept. MTTR less than 30 minutes.
  • All in one: 1/1, 1/3, 3/1 and 3/3 phase configurations
  • Able to operate even input phase sequence changes
  • Adjustable battery quantity: 20 to 40pcs.
  • Lowers spare part cost by using same boards for different ratings

Triple-mode  Intelligent  adjustable  battery  charger  for  fast  battery  recharge  —  Three charging modes ensure maximum battery availability:

  • Constant current charging provides maximum rated current to the battery until the voltage rises to a pre-determined limit.
  • Constant voltage charging allows the batteries to recover the final percentage of recharge capacity. A boost voltage is provided for a short term to reduce the battery recharge interval.
  • Float charging maintains the battery at the recommend voltage.

Adjustable battery charging time due to the level of the load to save from energy cost

SELF LOAD POWER TEST

  • Only 4% incremental energy consumption
  • Full-Power test of Rectifier, Inverter, Bypass, Chokes, Capacitors, Cables, Fuses
  • Customer Load safely supplied through maintenance bypass
  • Dummy-Load free

HIGH EFFICIENCY

  • Up to 95.5% at 30-75% load
  • 94% at 100% load;

COMMUNICATION

  • Local communication with  RS232 and RS485
  • 2 pcs configurable input contact
  • Relay board with  4pcs  standard alarms  and  expandable  up  to  12pcs optional relay contacts
  • GenSet
  • EPO
  • Solar Connectivity: Able  to  connect solar charge systems and configured from front panel LCD
  • Optional USB
  • Remote Monitoring Panel
  • Battery Temperature Sensor  for Temperature  Compensated Charging
  • JBUS, PROFIBUS Local connection
  • SNMP IT Manager monitoring
  • Environment sensors for  Data Centers  (Humidity,  Temperature, Smoke, etc.)
  • GSM, Telnet, GPRS communication
  • PC & Server shutdown
  • Web page remote monitoring
  • Building management system
  • Email alarm reporting
  • Remote monitoring 24/7 T.Service

OTHER OPTIONS

  • Input & Output isolation transformer External
  • Manual Bypass
  • Extended Additional Chargers
  • Higher IP configuration
  • Backfeed Protection
  • Full system isolation  with  EPO  by using  input,  output,  battery  and bypass contactors
  • Dual Input configuration
  • Common Battery for  parallel operations
  • Output synchronization contacts  for single  units  (STS  or  multiparallel applications)
  • Load Shedding by configuring output phases according to battery level